{"chunks": [{"bbox": {"x0": 0.05714286242252474, "x1": 0.9261857374728145, "y0": 0.06397306621269427, "y1": 0.9687168565158746}, "chunk_id": "6e8d4f6f-7400-4c84-997f-ef2ff9133654", "context_header": null, "is_table": true, "ordinal": 0, "page_from": 1, "page_to": 1, "text": " |  |  |  |  | CENTR | O NACI | ONAL D | E CON | TROL | DE ENE | RG\u00cdA |  |  | \n |  |  |  | FOR OPC 18 ver 01/06/2016 |  |  |  |  |  |  |  |  |  | \n |  |  |  |  | INFORME | DE FALL | A No. |  | 3-2025 |  |  |  |  | \n |  |  |  |  |  |  |  | O/T | N/A |  |  |  |  | \n | 1. EMPRESA DE GE |  | NERACI\u00d3N: |  | CELEC EP | - HIDRONA | CION |  |  |  |  |  |  | \n | 1.1 CENTRAL |  | MAR |  | CEL LANI | ADO DE W | IND |  |  |  |  |  |  | \n | 1.2 UNIDAD |  | U3 |  |  |  |  |  |  |  |  |  |  | \n | 2. FECHA: |  | 1/22/2025 |  |  |  | 3. HORA: | 10:58:09 |  |  |  |  |  | \n | 4. EVENTO: (1) |  |  |  |  |  |  |  |  |  |  |  |  | \n | Alrededor de las 10:58 del d\u00eda 22 de enero del 2025, encontr\u00e1ndose la U3 en generaci\u00f3n con 50 MW, se present\u00f3 la se\u00f1al de disparo\nProtAntincendio/Incendio generador/Bloqueo, generando la apertura del interruptor de m\u00e1quina 52G3 de la Unidad 3 de la Central Marcel Laniado de\nWind, seguida del bloqueo el\u00e9ctrico. |  |  |  |  |  |  |  |  |  |  |  |  | \n |  |  |  |  |  |  |  |  | Pertenece a su Empresa? |  |  |  |  | \n | 5. ELEMENTO FALL |  | ADO: |  |  |  |  |  | Si | x | No |  |  | \n | Manipulaci\u00f3n involuntaria del cable que estaba conectado al antiguo Sistema Contra Incendio del Generador por personal de limpieza al momento de\nrealizar limpieza en el nivel 20 |  |  |  |  |  |  |  |  |  |  |  |  | \n | 6. CAUSA PROBAB |  | LE: |  |  |  |  |  |  |  |  |  |  | \n | Propias de la instalaci\u00f3n / Equipos, material, dise\u00f1o / Falla Humana |  |  |  |  |  |  |  |  |  |  |  |  | \n | 7. CONDICIONES PR |  | EVIAS A LA F |  | ALLA: |  |  |  |  |  |  |  |  | \n |  |  |  |  | GENERACI\u00d3N EN UNIDADES |  |  |  | VOLTAJE |  |  |  |  | \n | 7.1 ELEMENTO FALLA |  | DO: |  | MW |  | MVAR |  | KV |  |  |  |  | \n |  |  |  |  | 50.00 |  | -1.8 |  | 13.8 |  |  |  |  | \n | 7.2 PROBLEMAS CON |  | POTENCIA |  |  |  |  |  |  |  |  |  |  | \n |  |  |  |  |  | MW |  | MVAR |  |  |  |  |  | \n | DISMINUCION DE POT |  | ENCIA |  |  |  |  |  |  |  |  |  |  | \n |  |  |  |  |  | FECHA INICIO | HORA INICIO | FECHA FIN | HORA FIN |  |  |  |  | \n | DURACION |  |  |  |  |  |  |  |  |  |  |  |  | \n |  |  |  |  |  | DESPEJADO | LLUVIA | VIENTO | DESCAR. ATM | OSF. | OTROS |  |  | \n | 7.2 CONDICIONES CLI |  | M\u00c1TICAS: |  |  | x |  |  |  |  |  |  |  | \n | 8. CONSECUENCIA |  | S SOBRE OTR |  | OS EQUIP | OS DEBIDO | A LA FAL | LA: |  |  |  |  |  | \n | EQUIPO |  |  |  | CONSECUENCIA |  |  |  |  |  |  |  |  | ", "token_count": 1180}, {"bbox": {"x0": 0.05714286242252474, "x1": 0.9261857374728145, "y0": 0.06397306621269427, "y1": 0.9687168565158746}, "chunk_id": "7dbd4c69-5768-4d8d-8a81-1e19d989255a", "context_header": null, "is_table": true, "ordinal": 1, "page_from": 1, "page_to": 1, "text": " |  |  |  |  | CENTR | O NACI | ONAL D | E CON | TROL | DE ENE | RG\u00cdA |  |  | \n | - |  |  |  | - |  |  |  |  |  |  |  |  | \n | 9. PROTECCIONES |  | Y DISYUNTOR |  | ES OPERA | DOS |  |  |  |  |  |  |  | \n | HORA |  | DISYUNTOR |  |  | REL\u00c9S |  |  | ALARMAS |  |  |  |  | \n | 10:58:09:198 |  |  |  |  |  |  |  | ProtAntincendio/Incendio generador/Bloqueo |  |  |  |  | \n | 10:58:09:230 |  |  |  |  |  |  |  | Secuencia/ParoEmerg/Estado/Activo |  |  |  |  | \n | 10:58:34:296 |  |  |  |  | Rele86E |  |  | Falla el\u00e9ctrica generador/Disparo |  |  |  |  | \n | 10:58:09:346 |  | 52G |  |  |  |  |  | 52G/Status/Abierto |  |  |  |  | \n | 10. HORA DECLARA |  | CI\u00d3N DE DIS |  | PONIBILID | AD DE EQU | IPO FALL | ADO: | 11:49:46 | 1/22/2025 |  |  |  | \n | 11. MANIOBRAS Y O |  | TRAS ACCIO |  | NES REAL | IZADAS: |  |  |  |  |  |  |  | \n | HORA |  | LUGAR |  |  | MANIOBRAS E | JECUTADAS |  |  |  |  |  |  | \n | 11h00 |  | Sala de control |  |  | Reste de Alarmas SCADA y CCM. |  |  |  |  |  |  |  | \n | 11h00 |  | Nivel 20 |  |  | Revisi\u00f3n del recinto del Generador |  |  |  |  |  |  |  | \n | 11h10 |  | Nivel 26 |  |  | Reset del tablero del Regulador de Velocidad |  |  |  |  |  |  |  | \n | 11h43 |  | Sala de control y Nivel 26 |  |  | Se comunica al Operador de Sala de control que de un reset del 86E en el tablero de\nprotecciones del Generador |  |  |  |  |  |  |  | \n | 11:44 |  | Sala de control |  |  | En coordinaci\u00f3n con CENACE, Se inicia la secuencia de arranque de la Unidad |  |  |  |  |  |  |  | \n | 13. CAUSA RAIZ, AC |  | CIONES CUR |  | ATIVAS, Y | ACCIONE | S CORREC | TIVAS: |  |  |  |  |  | \n | CAUSA RAIZ |  |  |  |  |  |  |  |  |  |  |  |  | ", "token_count": 806}, {"bbox": {"x0": 0.05714286242252474, "x1": 0.9023366497247219, "y0": 0.06397306621269427, "y1": 0.5354124566687632}, "chunk_id": "e145790f-5c42-4ecf-a0d3-ffb24364a8a0", "context_header": null, "is_table": true, "ordinal": 2, "page_from": 33, "page_to": 33, "text": " |  |  |  |  | CENTR | O NACI | ONAL D | E CON | TROL | DE ENE | RG\u00cdA |  | \n |  |  |  | FOR OPC 18 ver 01/06/2016 |  |  |  |  |  |  |  |  | \n |  |  |  |  | INFORME | DE FALL | A No. |  | 3-2025 |  |  |  | \n |  |  |  |  |  |  |  | O/T | N/A |  |  |  | \n | Manipulaci\u00f3n involuntaria del cable de la se\u00f1al de incendio del Generador manipulada por personal de limpieza. |  |  |  |  |  |  |  |  |  |  |  | \n | ACCI\u00d3N CURATIVA |  |  |  |  |  |  |  |  |  |  |  | \n | Restablecimiento de alarmas de protecci\u00f3n de unidad, SCADA |  |  |  |  |  |  |  |  |  |  |  | \n | ACCI\u00d3N CORRECTIVA |  |  |  |  |  |  |  |  |  |  |  | \n | En el tablero de controladores se abre la bornera seccionable referente a la se\u00f1al de bloqueo que proven\u00eda del tablero antiguo del Tab. Antincendio del\nGenerador |  |  |  |  |  |  |  |  |  |  |  | \n | 14 OBSERVACIONE |  | S, CONCLUSI |  | ONES Y RE | COMENDA | CIONES: |  |  |  |  |  | \n | \u00bb En el contrato relacionado con la modernizaci\u00f3n del Sistema Contra Incendio, una de las actividades realizadas fue el desmontaje del Tablero\nAntincendio del Generador. Sin embargo, el cableado correspondiente a las se\u00f1ales digitales de entrada, salida y bloqueo qued\u00f3 ubicado en una\nbandeja a nivel del piso. Esta bandeja est\u00e1 situada sobre un canal de drenaje de agua en el Nivel 20.\n\u00bb Durante las labores de limpieza realizadas en el nivel 20, el personal encargado verti\u00f3 agua en el piso, dirigi\u00e9ndola posteriormente al canal de\ndrenaje. En este proceso, el agua entr\u00f3 en contacto con los cables colocados en la bandeja, lo que provoc\u00f3 el incidente. La conducci\u00f3n de agua\nmezclada con tierra activ\u00f3 la se\u00f1al digital en el m\u00f3dulo de entrada \"ProtAntincendio/Incendio Generador/Bloqueo\". Como consecuencia, se gener\u00f3\nuna se\u00f1al de bloqueo el\u00e9ctrico, lo que desencaden\u00f3 autom\u00e1ticamente la secuencia de Paro de Emergencia.\n\u00bb El personal de Mantenimiento El\u00e9ctrico llev\u00f3 a cabo la inspecci\u00f3n correspondiente a la novedad detectada tras los trabajos realizados por la\nempresa contratada para la modernizaci\u00f3n del Sistema Contra incendio de la Central Marcel Laniado de Wind. Se comprometen a sacar estos cables\nque quedado en esta bandeja que esta a la altura del piso donde estaba antiguamente en el Tablero Contra incendio del Generador. |  |  |  |  |  |  |  |  |  |  |  | \n | (1) Conforme a la inform |  | aci\u00f3n proporci |  | onada o coo | rdinada con | el CENACE |  |  |  |  |  | \n | Personal turno: Operadores: Julio Silva - Fabio Jimenez; Supervisor: Xavier Barcia |  |  |  |  |  |  |  |  |  |  |  | \n | FIRMA DE RESPONSA |  | BILIDAD: |  |  |  |  |  |  |  |  |  | \n |  |  |  |  |  |  | FECHA DE | ENV\u00cdO: | 1/24/2025 |  |  |  | \n |  |  |  |  |  |  | HORA: |  | 12h00 |  |  |  | \n | Ing. Jonathan Riera |  |  |  |  |  |  |  |  |  |  |  | \n | F. AUTORIDAD COM |  | PETENTE |  |  |  |  |  |  |  |  |  | ", "token_count": 1037}]}